| Sign In | Join Free | My burrillandco.com |
|
| Ask Lasest Price | |
| Brand Name : | Macylab |
| Model Number : | UV-1500PC |
| Certification : | CE,FCC,FDA,ROHS,9001 |
| Price : | USD 720-USD 960/PCS |
| Payment Terms : | L/C, T/T, Western Union, MoneyGram, MoneyGram |
| Supply Ability : | 5000set/M |
| Delivery Time : | within 7 days |
Character
● ingle-chip microcomputer control, LCD Screen (128*64 Dots)
● Large LCD display can display multiple sets of data
● Huge memory space to store multiple sets of data and curves
● Auto zero,100% adjustment function
● Wavelength automatic adjustment
● Wrap lights, automatic filter change , large sample pool (5mm ~ 100mm)
● Standard samples having a maximum ten-point standard curve measurement functions built
● Direct input by K, B factor for quantitative measurement standard curve
● Can be directly input and the corresponding standard concentration values establish a standard curve for quantitative measurement
● Adjustable electric saving standard curve parameter measuring set, can save a plurality of standard curve
● Can be edited at any time of the standard curve , user-friendly
● General Parallel printer interface with or slightly beat interfaces can print the title bar, the measurement data , curve parameters , the standard curve and the curve sample points
● With USB interface
● PC control can be achieved through more accurate and flexible measurement requirements ( standard )
Software features
● Wavelength Scan: the measured object can be 190nm-1100nm full band spectrum scan , can also be segmented scan
● Kinetic tests: the time of the measured object scanning , timely detection of changes in concentration caused by changes in absorbance
● Quantitative measurement: by establishing a standard curve , the concentration can be measured in the analysis was
● Multi- wavelength testing : set a plurality of wavelengths simultaneously , the measured absorbance of a plurality of wavelengths in the test
● DNA / protein test: the test formula purity of nucleic acid and protein concentration analysis of DNA / protein
Technical Specifications
| Wavelength Range | 190~1100nm |
| Band Width | 2nm |
| Wavelength Accuracy | ±0.5nm |
| Wavelength Repeatability | ≤0.2nm |
| Photometric Accuracy | ±0.3% τ |
| Photometric Repeatability | 0.15% τ |
| Stray Light | ≤0.05% τ (220nm NaI,340nm NaNO2) |
| Stability | 0.001A/h@500nm |
| Photometric Mode | T,A,C,E |
| Wavelength Setting | Automatic |
| Photometric Display Range | -0.3~3A |
| Display Mode | LCD Screen (128*64 Dots). |
| Detector | Import Silicon Photodiode |
| Light Source | Import Deuterium Lamp & Tungsten Halogen Lamp |
| Power Requirement | AC 220V/50Hz 110V/60Hz |
| Power | 120W |
| Dimensions(W*D*H) | 480×350×220mm |
| Weight | 15Kg |
|