Sign In | Join Free | My burrillandco.com
Home > Laboratory Spectrophotometer >

Icp-6810 Inductively Coupled Plasma Optical Emission Spectrophotometer Laboratory

    Buy cheap Icp-6810 Inductively Coupled Plasma Optical Emission Spectrophotometer Laboratory from wholesalers
     
    Buy cheap Icp-6810 Inductively Coupled Plasma Optical Emission Spectrophotometer Laboratory from wholesalers
    • Buy cheap Icp-6810 Inductively Coupled Plasma Optical Emission Spectrophotometer Laboratory from wholesalers

    Icp-6810 Inductively Coupled Plasma Optical Emission Spectrophotometer Laboratory

    Ask Lasest Price
    Brand Name : macylab
    Model Number : Icp-6810
    Certification : ECM
    Price : 37970$
    Payment Terms : L/C, D/A, D/P, T/T, Western Union, MoneyGram
    Supply Ability : 1000pc
    • Product Details
    • Company Profile

    Icp-6810 Inductively Coupled Plasma Optical Emission Spectrophotometer Laboratory


    Introduction

    Product Description

    Inductively coupled plasma emission spectrometer(ICP6810) developed by Macylab Instruments with many years of technology accumulation. It is used to measure traces and traces of various substances (dissolvable in hydrochloric acid, nitric acid, hydrofluoric acid, etc.),and the content of metal elements or non-metallic elements. It is stable and reliable and with high degree of automation and easy operation. At present, instruments are widely applied in various fields such as rare earth, geology, metallurgy, chemical industry, environmental protection, clinical medicine, petroleum products, semiconductor, food, biological samples, criminal science, agricultural research and so on.
    Main features
    CONTENT RANGE
    Shipping/Storage Ambient Temperature15ºC-25ºC
    Shipping/Storage Relative Humidity≤70%
    Atmospheric pressure86-106 kPa
    Power Supply220±10V 50-60MHz
    Working Humidity≤70%
    Working Temperature15ºC-30ºC
    RFPower technical parameter
    Circuit typesolid-state RF power supply, with function of automatch
    Frequency27.12MHz±0.05%
    Frequency Stability<0.1%
    Power Output800W-1200W
    Power Output Stability<0.3%
    Escaped RF radiation30cm away from the instrument, electric field: E<2V/m
    Sampling System Technical Parameter
    Output working coil inner diameter25mm
    Torque tubeThree concentric, external diameter 20mm
    Coaxial nebulizerOuter diameter 6mm
    Double barrel atomizing chamberOuter diameter 34mm
    Gas Flow Controls
    Plasma Argon Flowmeter(100-1000)L/h (1.6-16L/min)
    Auxiliary Argon Flowmeter(10-100)L/h (0.16-1.66L/min)
    Carrier Argon Flowmeter(10-100)L/h (0.16-1.66L/min)
    Pressure Maintaining Valve(0-0.4MPa)
    Cooling Water:Temperature20-25ºC, Rate of Flow>5L/min, Hydraulic Pressure>0.1MPa
    Spectrometer
    OpticsCzerny-Turner type
    Focal length1000 mm
    GratingIon Beam Etching Holographic Grating, 3600L/mm or 2400L/mm
    Reciprocal linear dispersion0.26nm/mm
    Resolution≤ 0.007nm (3600 line grating);≤0.015nm (2400line grating)
    ElementWL(nm)LimitElementWL(nm)Limit
    La408.672<3.0Cr267.716<5.0
    Ce413.765<5.0Al396.152<5.0
    Pr414.311<5.0Zr343.823<5.0
    Nd401.225<5.0Ag328.068<3.0
    Sm360.946<10.0Sr407.771<1.0
    Eu381.967<1.0Au242.795<5.0
    Gd342.247<10.0Pt265.945<5.0
    Tb350.917<3.0Pd340.458<5.0
    Dy353.170<3.0Ir224.268<10.0
    Ho345.600<3.0Rh343.489<10.0
    Er337.271<3.0Ru240.272<5.0
    Tm313.126<3.0Ba455.403<1.0
    Yb369.419<1.0As228.812≤15
    Lu261.541<3.0Sb206.833≤15
    Y371.030<1.0Bi223.061≤10
    Sc335.373<1.0Hg253.652≤15
    Ta226.230<5.0Pb220.353≤15
    Nb313.340<5.0Ga294.364≤10
    Mn257.610<3.0Se203.985≤10
    Mg279.553<1.0Sn242.949≤20
    B249.773<10.0Te214.281≤10
    Zn213.856<3.0Ta226.230≤5.0
    Co228.616<3.0Th283.730≤10
    Si251.611<10.0Tl276.787≤30
    Ni232.003<5.0Re227.525≤5
    Cd226.502<3.0Ge209.426≤15
    Fe239.562<3.0Os225.585≤1
    Ca393.366<1.0W207.911≤10
    Mo281.615<5.0Cu324.754<3.0
    V310.230<5.0Li670.784≤3
    Be313.041<1.0Na588.995≤20
    Ti334.941<3.0K766.490≤60
    Wavelength range3600 line grating:(190nm~500) nm;2400 line grating: (190nm~800) nm
    Minimum pace of stepping motor≤0.0006 nm
    Exit Slit12μm;Entrance Slit:10μm
    Photoelectric Converter Performance
    Photomultiplier tube specificationR293/R928
    Negative HV on PMT0-1000V;Stability: <0.05%

    Our Advantages

    Quality
    1. Our products have good quality and very positive reputations in the market.
    2. Customers are very happy with them and have a lot of good comments about our intruments and service.
    Delivery Time
    1. We can get them ready 3-5 days after order confirmation for small orders.
    2. For big quantities, need to be confirmed.
    3. In most cases, fast delivery is guaranteed.
    Technical Support
    1. We have service manual. If not, detailed documents or videos will be provided.
    2. We can provide online training in our factory.
    3. We can have video conference at any time.
    Aftersales Support
    1. Respond to your questions within 10 minutes during our working time from 6:30 to 24:00, at most within 8 hours after 24:00 considering the time difference.
    2. Within warranty, we will solve the problem for you with no charge(except for consumables).
    3. You can call, text or email us at any time. We have good English speakers.
    Warranty Time
    One year and extendable

    Quality Icp-6810 Inductively Coupled Plasma Optical Emission Spectrophotometer Laboratory for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Macylab Instruments Inc.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)