    • Product Details
    • Company Profile

    Eight Lights Aas Atomic Absorption Spectroscopy Longitudinal Heating


    Macylab Eight Lights Longitudinal Heating Flame Graphite Furnace Integrated Atomic A Bsorption Spectrometer

    Product Description

    AA-1800EL atomic absorption spectrophotometer is absorted the latest international technology and famous universities jointly complete R & D, application experience with decades of spectral instrument. The products include the flame , graphite furnace and hydride generation system, can be equipped with various accessories, flexible configuration program can meet different customer demand. AA-1800 atomic absorption spectrometer can be used for analysis of complex samples ,full automatic multifunctional, various analysis methods can automatically switch, unmanned automatic analysis.
    AA-1800EL atomic absorption spectrophotometer is now widely used in scientific research,quality control, disease control, environmental protection, metallurgy, agriculture,chemical industry .Hardware and software design of innovation to ensure the accuracy,safety, ease of use in the analysis of samples, equipment maintenance, simple and convenient.

    Technical parameters


    Model

    AA-1800EL

    Light Source

    ≤8 lamps automatic turret, automatic alignment

    Power Supply

    110/220V (+5% ~ -10%), 60/50Hz; 5000VA

    Lamp Current

    pulsed power supply

    Optical System

    large 1800 /mm grating ruling, full closed optical system

    Wavelength Range

    185nm-900nm

    Wavelength Accuracy

    ±0.15nm

    Wavelength Repeatability

    <0.10nm

    Spectral Bandwidth

    0.1,0.2,0.4,0.7,1.0,1.4,2.0nm(7 steps with automatic changeover)

    Baseline Stability

    ≤±0.002A/30 min (Static) ≤±0.004A/30min (Dynamic)


    Flame Analytical System

    Detector

    Imported Photomultiplier Tube

    Burner Head

    Full Titanium Combustion Head, 50mm Or 100mm Generalcombustion Head

    Atomization Chamber

    Polymer Explosion-proof Spray Chamber

    Nebulizer

    Atomizer Efficient Glass Atomizer, Can Also Be Customized

    Ignition Type

    Microcomputer Control, Automatic Ignition

    Gas Control

    Automatic Gas Control System

    Detection Limits(Cu)

    0.002μg/mL

    Precision

    RSD≤0.5%


    Graphite Furnace Analytical System


    Heating ModeVertical Heating
    Temperature Control MethodVertical Optical Temprature Monitoring Graphite Tube Wall Temperature
    Temperature RangeRoom Temperature To 3000ºc
    The ProgramAutomatic Temprature Control Up To 20 Order
    Temprature ControlThe Furnace Enriched Up To 20 Times
    Characteristics Volume0.4*10-12g(cd)
    Detection Limit0.4*10-12g(cd)

    Precision

    RSD≤2%
    The Cooling WaterCan Choose Cooling Water Circulation System

    Safety

    The Graphite Tube Damage, Water Flow Air Pressure And Other Alarmtemperature Overheating Protection

    Main features

    Total reflection achromatic optical system
    The dispersion rate is 1800 lines/mm grating, a new type of self-collimating monochromator, all lenses are quartz-coated, the wide detection range and optical stability ensure the accuracy of analysis, and the blaze wavelength is 230nm grating spectroscopic system.
    Eight lamp sockets
    One lamp works, up to seven lamps can be preheated, which saves lamp replacement and preheating time, and makes element measurement faster and more convenient.
    Full automation
    The instrument adopts a fully automatic design. Except for the power switch of the main engine, the functions of the lamp frame control, wavelength scanning, slit adjustment and two-dimensional moving platform of the instrument are all controlled by software.
    Background correction system
    It has two background correction modes: deuterium lamp and self-absorption. When the background signal is 1A, the ability to deduct the background is more than 60 times.
    Analysis software with independent intellectual property rights, complete functions and powerful performance
    The user-friendly operation interface makes your operation as easy as the palm of your hand. You can switch between Chinese and English Windows style software interfaces, automatic qualitative and quantitative analysis, automatic calculation of element content, and automatic generation of test reports.


    Characteristics of flame system
    Polymer atomization chamber
    Polymer material anti-corrosion spray chamber, acid and alkali resistance, including hydrofluoric acid, whether it is organic or inorganic solution can get better sensitivity and stability;
    Titanium burners
    Titanium burner, optional 50mm and 100mm burner, air-cooled premixed type, corrosion resistance, high salt resistance, greatly improving the efficiency of flame and the accuracy of flame analysis;
    High-precision anti-clogging atomizer
    Patented atomizer, high atomization efficiency, easy maintenance and replacement.
    The mass flow controller realizes the acetylene flow control
    The mass flow controller precisely controls the acetylene flow with an accuracy of 1ml/min, and dynamically monitors the flow, which is easy to use, safe and reliable.
    More safety protection measures to make sample analysis more secure and reliable
    Use high-sensitivity detectors to monitor acetylene leakage in real time;
    Adopt high-precision pressure sensor to monitor acetylene pressure in real time;
    Adopt high-precision pressure sensor to monitor the air pressure of acetylene pressure;
    Adopt micro switch and fireproof latch to monitor the state of the combustion head;
    Adopt photodiode to monitor the flame state in real time;


    Features of graphite furnace system
    Integrated design
    The graphite furnace power supply and atomic absorption host are located in one instrument, which shortens the cable length, reduces the electromagnetic interference of the graphite furnace power supply to the outside world, and improves the heating efficiency of the graphite tube.
    The graphite furnace has high temperature control accuracy and fast heating rate
    Using high-power transformers, micro-resistance cables and light-controlled heating methods, and with software and hardware temperature correction systems, the temperature control accuracy in high temperature segments can reach ±1%.
    More safety protection measures to make sample analysis more secure and reliable
    The cooling water of graphite furnace has real-time monitoring and protection of flow;
    Monitoring of carrier gas pressure by pressure sensor
    Graphite furnace temperature monitoring by photodiode
    Automatic carrier gas flow control
    The gas inside and outside the graphite furnace are all automatically controlled by the computer according to the software heating process.
    150-position rotary graphite furnace automatic sampler
    Polar coordinate turntable graphite furnace automatic sampler, high positioning accuracy, stable and reliable operation, easy to use and maintain.


    Our Advantages

    Quality
    1. Our products have good quality and very positive reputations in the market.
    2. Customers are very happy with them and have a lot of good comments about our intruments and service.
    Delivery Time
    1. We can get them ready 3-5 days after order confirmation for small orders.
    2. For big quantities, need to be confirmed.
    3. In most cases, fast delivery is guaranteed.
    Technical Support
    1. We have service manual. If not, detailed documents or videos will be provided.
    2. We can provide online training in our factory.
    3. We can have video conference at any time.
    Aftersales Support
    1. Respond to your questions within 10 minutes during our working time from 6:30 to 24:00, at most within 8 hours after 24:00 considering the time difference.
    2. Within warranty, we will solve the problem for you with no charge(except for consumables).
    3. You can call, text or email us at any time. We have good English speakers.
    Warranty Time
    One year and extendable

    Our Company
    Double Beam Touch Screen Vis UV Visible Spectrophotometer for Lab Eight Lights Aas Atomic Absorption Spectroscopy Longitudinal Heating


    FAQ


    Q1: Why choose Macy Lab?
    A1: Professional manufacturer with more than 10 years experience
    Mainly exported to the European and American markets, and we are also involved in other markets.

    Q2: Are you a factory or a trading company?
    A2: We are professional manufacturer of UV/Vis Spectrophotometers, Atomic Absorption Spectrophotometer, Micro-volume UV/VIS spectrophotometers , ICP item and Nucleic Acid Automatic Extraction System. And we have three R&D and production bases in Shanghai, Beijing and Jiangsu, and three wholly-owned subsidiaries.

    Q3: OEM , ODM acceptable or not?
    A3: Absolutely, yes.

    Q4: What can i get the price?
    A4: Usually we quote within 12 hours after we get your enquiry

    Q5:What are your Delivery terms?
    A5: We accept FOB,EXW,CFR . You can choose the one which is most convenient or cost-effective for you.

    Q6: What about the after-sale service?
    A6: Our spectrophotometer consumables are fully equipped, good after-sales service system and one-year warranty commitment, which can solve customer's worries.
    We can ensure our customers to purchase the components and parts within 5 years. And the product updates and replacement will not be affected.

    Q7: What about the M.O.Q?
    A7: Usually we don' t have M.O.Q, we can offer even only 1 unit, while , you are welcome to order in bulk, and we are quite pleasure to offer a big discount.

    Q8: Sample order is OK?
    A8: Sample order is no problem.

    Q9: What' s kind of shipment for customer choosing?
    A9: Usually ship by sea, by air.
    We can also provide reasonable solutions according to your transportation requirements.

    Q10: Are your operation keypad, interface, software and manual in English version?
    A10: Yes, its operation keypad, interface, software and manual in switching interface between Chinese and English.

    Q11: What areas and applications can it be used?
    Q11: It can be used for qualitative or quantitative meansurements for water solution in the following areas: metallurgy, pharmacy, food, health, institutes, biological chemistry, life science, petrochemical industry, mining, quality control, environmental protection, etc.

    Q12: Which payment can be acceptable ?
    A12: We could accept the payment by T/T, Paypal, Western Union,L/C, etc.

    Q13: What is the delivery time?
    A13: Normally 15-30 days,specific delivery date would depend on the production season and order quantity.

    Q14: Can I get a sample?
    A14: Yes,please contact our staff for more information.

    Q15: How about OEM and ODM?
    A15: More than 10 years experience in OEM and ODM.

    Q16: What kinds of models do you make ?
    A16: We specializing in various optical analyzer. Including Atomic Absorption Spectrophotometer,Ultraviolet and Visible Spectrophotometer,Atomic fluorescence photometer,ICP-AES/ICP-MS

    Q17: What standard accessories are included?
    A17: Main unit, 4 pcs of 1cm glass cuvette(all models) and 2 pcs of 1cm quartz cuvette(UV models), With user manual and power cable.

    Q18: Is PC software included?
    A18:The PC software(CFR 21 or regular one) is optional. Also the thermal printer is available on requested.

    Q19: Why the reading is red and reach its maximum value 3.00Abs?
    A19: Probably you use the glass cuvette in UV range.

    Q20: Why the wavelength calibration or self checking fail?
    A20: The deuterium lamp is turned off or there is something wrong with the D2 lamp, like the fuse, triode or the lamp itself.

    Q21: Why is the reading is not as accurate as before?
    A21: Do the wavelength calibration before testing or restore the device to its default factory settings.

    Q22: Why PC software can not be installed successfully?
    A22: Close your anti-virus software on the computer and do it again.

    Q23: Why the software can not be connected successfully?
    A23: Please return to its initial interface and don't enter any menu when connecting to PC software. And the device can not be operated once connected to software. Secondly, unload the previous/old version PC software if there is.

    Q24: Can the data transferred to USB or PC?
    A24: Yes, you can transfer the saved data on the device to a USB then copy it to PC, or you can save the data directly on the PC via software.

    Q25: Why the Abs value is negative(lower than zero).
    A25: Do the blanking or change the reference sample